The tank pressure gauge on the D55168 and D55146 is +/-12 psi. The safety valve is set for 225 and will prevent the tank from being pressurized too high.
When replacing a belt on an EHP compressor (ie. D55168), proper tension is critical. If there is not enough tension, the belt will spin and wear the rubber surface off. If there is too much tension...
It will take approximately 5 minutes to go from 0-200 psi.
Canada requires a lower amp draw (15 amp) than the US (16.5 amp), so the motor cannot be run as hard, and thus the air delivery is a bit lower.
No, the tank pressure goes up to 200 PSI, but the max regulated amount is about 150 PSI.
Answer See the chart below. CFM PSI7.2 106.7 256.2 405.6 604.8 90
Answer The CFM ratings of D55168 Types 1, 2, and 3 are as follows: CFM PSI 8.1 10 7.5 25 7 40 6.3 60 5.4 90 The CFM ratings for D55168...
Answer The D55168 is rated for a life of approximately 500 hours. That time will shorten in dry or abrasive environments and lengthen in a normal workshop environment. The motor brushes are the lif...
Answer The D55168 is rated at 1.8 HP continuous.
Answer The sleeve on the pump of this unit is cast iron.